Safety 1st TR233 Specifiche Pagina 62

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 79
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 61
4.5 THE PROCEDURE
4.5.1 VCO Alignment
4.5.1.1 VHF RECEIVE VCO
Step
No
Result
Measured by
Result
Measured at
Adjust
Result Notes
1
Switch on power
Select ch. 3..
Highest freq.
channel.
2
DVM, dc
volt, range
TP402 L407 15.0 +10.2V
3
DVM, dc
volt. range
TP402 Select channel 1 3.OV to 5.OV
Lowest freq.
channel.
4 Disconnect DVM.
4.5.1.2 VHF TRANSMIT VCO
Step
No
Result
Measur
ed by
Result
Measured at
Adjust
Result Notes
1
Switch on power.
Select ch. 3.
Highest freq.
channel
2
Activate PTT.
3
DVM, dc
volt. range.
TP402 L445 15.0 -/+ 0.2V
4 Disable PTT
5
DVM, do
volt. range
TP402
Select ch. 1
and activate PTT
3.0 to 5.0V Lowest freq. ch.
6
Disable PTT
Disconnect DVM
4.5.2 Transmitter Power Adjustment
Step
No
Result
Measured by
Result
Measured at
Adjust
Result Notes
1
Switch on power.
Select ch. 2.
Mid freq channel for
high power
2
Activate PTT
3 Power Meter
Antenna
socket
R581 25.0 -/+ 1 watt
Section 4 Page 4
Vedere la pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 78 79

Commenti su questo manuale